Product Range

We are able to use our knowledge of onsite power to provide a number of generation solutions, such as gas-fuelled generators.

We take a flexible approach to our product offering and are able to provide a standard product offering as well as bespoke solutions.

STANDARD COGENERATION SYSTEMS

Natural Gas (50Hz)

Natural Gas (50Hz)
Cogeneration Unit                                              Electrical Output 
kW                
Heat Output
kW
(LTHW Only)            
Fuel Input  (net)Fuel Input(gross)
ENER·G 4y4814.516
ENER·G 10y101732.636
ENER·G 25y253874.683
ENER·G 35M3355112124
ENER·G 50M5176163180
ENER·G 70M70104204226
ENER·G 100100165303335
ENER·G 110110181325360
ENER·G 125122196357395
ENER·G 135E135215392435
ENER·G 150150231427474
ENER·G 165165270500553
ENER·G 185185280522580
ENER·G 210210345625692
ENER·G 230228358649718
ENER·G 310PT307357820907
ENER·G 375PT3754019781082
ENER·G 425PT42546811191238
ENER·G 500PT50052712981436
ENER·G 770MU77083418682066
ENER·G 1000PT1000122825872861
ENER·G 1030CA1027141428673171
ENER·G 1030CH1027131728853191
ENER·G 1150CB1150142830563380
ENER·G 1165MU1164126028243123
ENER·G 1550MU1562167737644163
ENER·G 1600CE1600163439004313
ENER·G 1950MU1948210547045203
ENER·G 2000CE 2000 2176 4941 5465

  • Output figures are based on operation at ISO conditions and are quoted from manufacturers declared performance figures subject to change without notice
  • Standard Units built for LTHW operation (820C). Steam options available.
  • Fuel consumption figures are based on the gross calorific value of British Natural Gas
  • Output figures may vary under different operating regimes and site-specific characteristics. As such the figures shown are for guidance only.
  • Units built for 400V, 50Hz operation
  • Energy tolerances - Fuel 5% - Useable heat 7%

Natural Gas (60Hz)

Natural Gas (60Hz)
Cogeneration UnitElectrical Output kWHeat Output kWFuel Input kW
ENER·G 55F5584188
ENER·G 75F75115259
ENER·G 155F155230495
ENER·G 195F195296629
ENER·G 265F265 404 834 
ENER·G 395F3955331271 

  • Output figures are based on operation at ISO conditions and are quoted from manufacturers declared performance figures subject to change without notice
  • Standard Units built for LTHW operation (820C). Steam options available.
  • Fuel consumption figures are based on the gross calorific value of British Natural Gas
  • Output figures may vary under different operating regimes and site-specific characteristics. As such the figures shown are for guidance only.
  • Units built for380V, 60Hz operation

Biogas (50Hz / 60% Methane)

Biogas (50Hz / 60% Methane)
Cogeneration UnitElectrical Output kWHeat Output kWFuel Flow
ENER·G 30MB304515M³/hr
ENER·G 50MB507025M³/hr
ENER·G 80B8013038M³/hr
ENER·G 100B10015648M³/hr
ENER·G 150B15021869M³/hr
ENER·G 190B19029092M³/hr
ENER·G 190MB19020876M³/hr
ENER·G 250MB250277101M³/hr
ENER·G 305PTB305368130M³/hr
ENER·G 375PTB375421157M³/hr
ENER·G 425PTB425500180M³/hr
ENER·G 500PTB500563210M³/hr
ENER·G 1095CB10941215485M³/hr
ENER·G 1950CB19502114759M³/hr

*Contact the Cogeneration Sales Team on +44 (0) 161 745 7450

  • Output figures are based on operation at ISO conditions and are quoted from manufacturers declared performance figures subject to change without notice
  • Standard Units built for LTHW operation (820C). Steam options available.
  • Fuel consumption figures are based on the gross calorific value of Biogas
  • Output figures may vary under different operating regimes and site-specific characteristics. As such the figures shown are for guidance only.
  • Units built for 400V, 50Hz operation
  • Energy tolerances - Fuel 5% - Useable heat 7%

Propane (50Hz)

Propane (50Hz)
Cogeneration UnitLoadingElectrical Output kWHeat Output kWFuel Input
ENER·G 75PFull Load75140285
ENER·G 140PFull Load140246499
ENER·G 280PFull Load280460927

  • Output figures are based on operation at ISO conditions and are quoted from manufacturers declared performance figures subject to change without notice
  • Standard Units built for LTHW operation (820C). Steam options available.
  • Fuel consumption figures are based on the gross calorific value of Propane
  • Output figures may vary under different operating regimes and site-specific characteristics. As such the figures shown are for guidance only.
  • Units built for 400V, 50Hz operation
  • Energy tolerances - Fuel 5% - Useable heat 7%

Biodiesel (50Hz)

Cogeneration Unit            Electrical Output kW     Heat Output kW     
(LTHW Only)  
Fuel Input     
 ENER·G 130BD     130 134 37
 ENER·G 190BD 190 193 52
 ENER·G 340BD 340 319 90
 ENER·G 385BD 385 365 102

  • Output figures are based on operation at ISO conditions and are quoted from manufacturers declared performance figures subject to change without notice. Fuel consumption figures are +/-10% and based upon a specific grade of biodiesel – other grade may alter energy outputs
  • Maximum return water temperature quoted at rated output.  Units will operate at up to 5 Celsius degree above the maximum return water temperature at reduced output.
  • Fuel consumption figures are based on biodiesel to EN14214
  • Output figures may vary under different operating regimes and site-specific characteristics.  As such the figures shown are for guidance only.
  • Units built for 400V, 50Hz 3 phase operation
  • Performance figures quoted are subject to the original engine manufacturer’s tolerances